Product Details
I. Product Overview
This product is a split-core current transformer designed for measuring cable line currents. The input cable passes through the central aperture of the device, and a secondary current is output at a specific ratio. By connecting a sampling resistor in series at the output terminal, the current signal can be converted into a voltage signal.
II. Electrical Parameters
Project | Parameters | Remarks | |
| Electrical parameters | Primary current ratio | 1 ~400A | / |
Secondary current | 0.5 ~100mA | / | |
Input frequency | 50 ~60Hz | / | |
Accuracy level | 0.5S | / | |
Angle difference change | < 15 (rated 1%~120%) | / | |
variation in hole ratio | <; 0.15 (change in ratio of 10mm diameter wire at different positions inside the inner hole) | / | |
Load resistance | <; 10 Ω | / | |
Open circuit voltage | <; 10V | / | |
Output terminals | Customizable | / | |
Leads | Customizable | / | |
Performance Parameters | Operating Temperature | -40 ~75 degrees | / |
Storage temperature | -40 ~80 degrees | / | |
power frequency withstand voltage | >; AC3000V | / | |
Puncture power clip | can be optionally equipped with clamping module and puncture power module | / |
III. Dimensional Drawing (Unit: mm)
Dimensional Drawing without Piercing Energy-Harvesting Clamp
Dimensional Drawing with Piercing Energy-Harvesting Clamp

ZH